mirror of
https://github.com/SebastianStork/nixos-config.git
synced 2026-03-22 17:49:07 +01:00
srv-core: Add fancontrol
This commit is contained in:
parent
5c2647ca56
commit
dc95d6fd77
1 changed files with 29 additions and 0 deletions
|
|
@ -42,4 +42,33 @@
|
|||
};
|
||||
};
|
||||
};
|
||||
|
||||
# Ensure pwm2_enable is set to 2 (automatic) before fancontrol starts,
|
||||
# because the IT8613E can't transition 0 -> 1 (manual) directly,
|
||||
# but can do 2 -> 1 which fancontrol requires.
|
||||
systemd.services.fancontrol-pwm-init = {
|
||||
description = "Initialize IT8613E PWM mode for fancontrol";
|
||||
before = [ "fancontrol.service" ];
|
||||
requiredBy = [ "fancontrol.service" ];
|
||||
serviceConfig.Type = "oneshot";
|
||||
script = "echo 2 > /sys/devices/platform/it87.2608/hwmon/hwmon*/pwm2_enable";
|
||||
unitConfig.ConditionPathExists = "/sys/devices/platform/it87.2608";
|
||||
};
|
||||
|
||||
hardware.fancontrol = {
|
||||
enable = true;
|
||||
config = ''
|
||||
INTERVAL=5
|
||||
DEVPATH=hwmon1=devices/platform/coretemp.0 hwmon2=devices/platform/it87.2608
|
||||
DEVNAME=hwmon1=coretemp hwmon2=it8613
|
||||
FCTEMPS=hwmon2/pwm2=hwmon1/temp1_input
|
||||
FCFANS=hwmon2/pwm2=hwmon2/fan2_input
|
||||
MINTEMP=hwmon2/pwm2=70
|
||||
MAXTEMP=hwmon2/pwm2=100
|
||||
MINSTART=hwmon2/pwm2=35
|
||||
MINSTOP=hwmon2/pwm2=25
|
||||
MINPWM=hwmon2/pwm2=0
|
||||
MAXPWM=hwmon2/pwm2=255
|
||||
'';
|
||||
};
|
||||
}
|
||||
|
|
|
|||
Loading…
Add table
Add a link
Reference in a new issue