mirror of
https://github.com/SebastianStork/nixos-config.git
synced 2026-03-22 16:39:07 +01:00
srv-core: Simplify fancontrol initialization
This commit is contained in:
parent
4a73ee7b8d
commit
6774abfb45
1 changed files with 1 additions and 12 deletions
|
|
@ -43,18 +43,6 @@
|
|||
};
|
||||
};
|
||||
|
||||
# Ensure pwm2_enable is set to 2 (automatic) before fancontrol starts,
|
||||
# because the IT8613E can't transition 0 -> 1 (manual) directly,
|
||||
# but can do 2 -> 1 which fancontrol requires.
|
||||
systemd.services.fancontrol-pwm-init = {
|
||||
description = "Initialize IT8613E PWM mode for fancontrol";
|
||||
before = [ "fancontrol.service" ];
|
||||
requiredBy = [ "fancontrol.service" ];
|
||||
serviceConfig.Type = "oneshot";
|
||||
script = "echo 2 > /sys/devices/platform/it87.2608/hwmon/hwmon*/pwm2_enable";
|
||||
unitConfig.ConditionPathExists = "/sys/devices/platform/it87.2608";
|
||||
};
|
||||
|
||||
hardware.fancontrol = {
|
||||
enable = true;
|
||||
config = ''
|
||||
|
|
@ -69,4 +57,5 @@
|
|||
MINSTOP=hwmon2/pwm2=25
|
||||
'';
|
||||
};
|
||||
systemd.services.fancontrol.preStart = "echo 2 > /sys/devices/platform/it87.2608/hwmon/hwmon*/pwm2_enable";
|
||||
}
|
||||
|
|
|
|||